Stir the mixture with a glass rod until solution is complete, allow the solution to stand for 15 minutes, unless otherwise directed, and compare the color of the solution with that of the specified matching fluid in a comparison container, which also is of colorless glass and has the same internal and cross-section dimensions, viewing the fluids transversely against a background of white porcelain or white glass.
Special attention is directed to the importance of the concentration of sulfuric acid used in this test. The reagent of the required strength, i.e., 95.0 ± 0.5 percent of H2SO4, is designated as a Test Solution.