Packaging and storage
Preserve in single-dose glass or plastic containers. Glass containers are preferably of Type I or Type II glass.
Labeling
The label states the total osmolar concentration in mOsmol per L. Where the contents are less than 100 mL, or where the label states that the Injection is not for direct injection but is to be diluted before use, the label alternatively may state the total osmolar concentration in mOsmol per mL.
Bacterial endotoxins 85
It contains not more than 0.5 USP Endotoxin Unit per mL for Injections containing less than 5% of dextrose and not more than 10.0 USP Endotoxin Units per g for Injections containing between 5% and 70% of dextrose.
[notePrior to analysis, dilute Injections containing more than 10% of dextrose to a concentration of 10% of dextrose.
]
Identification
It responds to the
Identification test under
Dextrose.
pH 791:
between 3.2 and 6.5, determined on a portion to which 0.30 mL of saturated potassium chloride solution has been added for each 100 mL and which previously has been diluted with water, if necessary, to a concentration of not more than 5% of dextrose.
Heavy metals 231
Transfer a volume of Injection, equivalent to 4.0 g of dextrose, to a suitable vessel, and adjust the volume to 25 mL by evaporation or addition of water, as necessary: the limit is 0.0005
C%, in which
C is the labeled amount, in g, of C
6H
12O
6·H
2O per mL of Injection.
Limit of 5-hydroxymethylfurfural and related substances
Dilute an accurately measured volume of Injection, equivalent to 1.0 g of C6H12O6·H2O, with water to 250.0 mL. Determine the absorbance of this solution in a 1-cm cell at 284 nm, with a suitable spectrophotometer, using water as the blank: the absorbance is not more than 0.25.
Other requirements
It meets the requirements under
Injections 1.
Assay
Transfer an accurately measured volume of Injection, containing 2 to 5 g of dextrose, to a 100-mL volumetric flask. Add 0.2 mL of 6 N ammonium hydroxide, dilute with water to volume, and mix. Determine the angular rotation in a suitable polarimeter tube (see
Optical Rotation 781). Calculate the percentage (g per 100 mL) of dextrose (C
6H
12O
6·H
2O) in the portion of Injection taken by the formula:
(100/52.9)(198.17/180.16)AR
in which 100 is the percentage; 52.9 is the midpoint of the specific rotation range for anhydrous dextrose, in degrees; 198.17 and 180.16 are the molecular weights for dextrose monohydrate and anhydrous dextrose, respectively;
A is 100 mm divided by the length of the polarimeter tube, in mm; and
R is the observed rotation, in degrees.