Chromatographic purity
Proceed as directed in the
Assay, except to use, instead of the
Assay preparation, a test solution prepared by dissolving Doxorubicin Hydrochloride in
Mobile phase to obtain a solution containing about 0.5 mg per mL. From the chromatogram of the test solution, calculate the percentage of impurities taken by the formula:
100S/(S + r),
in which
S is the sum of the responses of the minor component peaks; and
r is the response of the major doxorubicin peak: the total of any impurities detected is not more than 2.0%.
Limit of solvent residues (as acetone and alcohol)
Standard solution
Transfer to a 100-mL volumetric flask about 200 mg of acetone, 300 mg of dehydrated alcohol, and 1000 mg of dioxane, each accurately weighed, and mix. Dilute with water to volume, and mix. Transfer 5.0 mL of the resulting solution to a 50-mL volumetric flask, dilute with water to volume, and mix. This solution contains about 0.2 mg of acetone, 0.3 mg of C2H5OH, and 1 mg of dioxane per mL.
Solvent
Transfer about 100 mg of dioxane, accurately weighed, to a 100-mL volumetric flask, dilute with water to volume, and mix.
Test solution
Dissolve about 200 mg of Doxorubicin Hydrochloride in 3.0 mL (3.0 g) of Solvent.
Chromatographic system (see Chromatography 621)
The gas chromatograph is equipped with a flame-ionization detector and a 4-mm × 2-m column packed with 8% to 10% liquid phase G16 and 2% potassium hydroxide on 100- to 120-mesh support S1A. The column temperature is maintained at about 60
, and helium is used as the carrier gas. Adjust the column temperature and carrier gas flow rate so that dioxane elutes in about 6 minutes. Chromatograph the
Standard solution, and record the peak responses as directed for
Procedure: the relative retention times are about 0.2 for acetone, 0.5 for alcohol, and 1.0 for dioxane; the resolution,
R, between adjacent peaks is not less than 2.0; the tailing factor for the alcohol peak is not more than 1.5; and the relative standard deviations of the ratios of the peak responses of the acetone and dioxane peaks and of the alcohol and dioxane peaks for replicate injections is not more than 4.0%.
Procedure
Separately inject equal volumes (about 1 µL) of the
Standard solution and the
Test solution into the chromatograph, record the chromatograms, and measure the areas for the major peaks. Calculate the percentage, by weight, of acetone (CH
3COCH
3) and alcohol (C
2H
5OH), respectively, in the portion of Doxorubicin Hydrochloride taken by the same formula:
100(CA / CD)(DU / WU)(RU / RS),
in which
CA is the concentration, in mg per mL, of acetone or alcohol in the
Standard solution; CD is the concentration, in mg per mL, of dioxane in the
Standard solution; DU is the total quantity, in mg, of dioxane in the
Test solution; WU is the quantity, in mg, of Doxorubicin Hydrochloride taken to prepare the
Test solution; and
RU and
RS are the area ratios of the analyte peak (acetone or alcohol) to the dioxane peak obtained from the
Test solution and the
Standard solution, respectively: not more than 0.5% of acetone is found; and the total of acetone and alcohol is not greater than 2.5%. Use the combined percentage of acetone and alcohol obtained to calculate the result obtained as directed in the
Assay on the solvent-free basis.
Assay
Mobile phase
Prepare a suitable mixture of water, acetonitrile, methanol, and phosphoric acid (540:290:170:2). Dissolve 1 g of sodium lauryl sulfate in 1000 mL of this solution, adjust with 2 N sodium hydroxide to a pH of 3.6 ± 0.1, and degas. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Resolution solution
Dissolve about 10 mg of Doxorubicin Hydrochloride in 5 mL of water, add 5 mL of phosphoric acid, and allow to stand for about 30 minutes. Adjust with 2 N sodium hydroxide (about 37 mL) to a pH of 2.6 ± 0.1, add 15 mL of acetonitrile and 10 mL of methanol, mix, and filter. [NOTEPortions of this solution may be frozen until needed, then thawed, and mixed before use.]
Standard preparation
Dissolve an accurately weighed quantity of
USP Doxorubicin Hydrochloride RS in
Mobile phase to obtain a solution having a known concentration of about 0.1 mg per mL.
Assay preparation
Transfer about 20 mg of Doxorubicin Hydrochloride, accurately weighed, to a 200-mL volumetric flask, add Mobile phase to volume, and mix.
Chromatographic system (see Chromatography 621)
The chromatograph is equipped with a 254-nm detector and a 4.6-mm × 25-cm column that contains packing L13. The flow rate is about 1.5 mL per minute. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the tailing factor for the doxorubicin peak is not less than 0.7 and not more than 1.2; the column efficiency, determined from the doxorubicin peak, is not less than 2250 theoretical plates; and the relative standard deviation for replicate injections is not more than 1.0%. Chromatograph the
Resolution solution, and record the peak responses as directed for
Procedure: the relative retention times are about 0.6 for doxorubicinone and 1.0 for doxorubicin; and the resolution,
R, between doxorubicinone and doxorubicin is not less than 5.5.
Procedure
Separately inject equal volumes (about 20 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of C
27H
29NO
11·HCl in the Doxorubicin Hydrochloride taken by the formula:
0.2CP(rU / rS),
in which
C is the concentration, in mg, of
USP Doxorubicin Hydrochloride RS in each mL of the
Standard preparation; P is the content, in µg per mg, of C
27H
29NO
11·HCl in the
USP Doxorubicin Hydrochloride RS; and
rU and
rS are the responses of the doxorubicin peak obtained from the
Assay preparation and the
Standard preparation, respectively.