Chromatographic purity
Solution A:
water.
Solution B
Prepare a filtered and degassed mixture of acetonitrile, water, and triethylamine (160:40:1). Adjust with phosphoric acid to a pH of 7.0.
Diluent
Prepare a mixture of Solution A and Solution B (9:1).
Blank solution
Prepare a mixture of Diluent and methanol (9:1).
Mobile phase
Use variable mixtures of
Solution A and
Solution B as directed for
Chromatographic system. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
System suitability solution
Dissolve a suitable quantity of
USP Lansoprazole Related Compound A RS in methanol, and dilute quantitatively, and stepwise if necessary, to obtain a solution having a known concentration of about 0.025 mg per mL. Pipet 1 mL of this solution into a 10-mL volumetric flask, dilute with
Diluent to volume, and mix.
Standard solution
[NOTEInject within 10 minutes of preparation.
] Dissolve an accurately weighed quantity of
USP Lansoprazole RS in methanol, and dilute quantitatively, and stepwise if necessary, with methanol to obtain a solution having a known concentration of about 25 µg per mL. Pipet 1 mL of this solution into a 10-mL volumetric flask, dilute with
Diluent to volume, and mix. The final concentration of the
Standard solution is about 2.5 µg per mL.
Test solution
[NOTEInject within 10 minutes of preparation.] Transfer about 125 mg of Lansoprazole, accurately weighed, to a 50-mL volumetric flask, dissolve in and dilute with methanol to volume, and mix. Pipet 1 mL of this solution into a 10-mL volumetric flask, and dilute with Diluent to volume.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 285-nm detector and a 4.6-mm × 15-cm column that contains 5-µm packing L1. The flow rate is about 0.8 mL per minute. The chromatograph is programmed as follows.
Time (minutes) |
Solution A
(%) |
Solution B
(%) |
Elution |
040 |
90®20 |
10®80 |
linear gradient |
4050 |
20 |
80 |
isocratic |
5051 |
20®90 |
80®10 |
linear gradient |
5160 |
90 |
10 |
isocratic |
Chromatograph the
Resolution solution, and record the peak responses as directed for
Procedure: the resolution,
R, between lansoprazole and lansoprazole related compound A is not less than 6. Chromatograph the
System suitability solution, and record the peak responses as directed for
Procedure: the relative standard deviation for replicate injections is not more than 3%.
Procedure
Separately inject equal volumes (about 40 µL) of the
Blank solution, the
Standard solution, and the
Test solution into the chromatograph, record the chromatograms, and identify the lansoprazole peak and the peaks due to the impurities listed in
Table 1. Measure the areas for the major peaks, excluding the peaks obtained from the
Blank solution. Calculate the percentage of each impurity in the portion of Lansoprazole taken by the formula:
50(CF / W)(ri / rS),
in which
F is the relative response factor for each impurity peak (see
Table 1 for values);
C is the concentration, in µg per mL, of
USP Lansoprazole RS in the
Standard solution; W is the weight, in mg, of Lansoprazole taken for the
Test solution; ri is the peak response for each impurity obtained from the
Test solution; and
rS is the peak response for lansoprazole obtained from the
Standard solution: In addition to not exceeding the limits for impurities in
Table 1, not more than 0.6% of total impurities is found.
Table 1
Approximate Relative Retention Time |
Relative Response Factor (F) |
Name |
Limit (%) |
1.1 |
1.22 |
Lansoprazole related compound A |
0.4 |
0.8 |
0.76 |
Impurity B |
0.1 |
1.2 |
1.27 |
Impurity C |
0.1 |
|
1.00 |
Other individual impurity |
0.1 |
Assay
Diluent
Prepare a mixture of water, acetonitrile, and triethylamine (60:40:1), and adjust with phosphoric acid to a pH of 10.0.
Mobile phase
Prepare a filtered and degassed mixture of water, acetonitrile, and triethylamine (60:40:1). Adjust with phosphoric acid to a pH of 7.0. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Internal standard solution
Dissolve an accurately weighed quantity of 4¢-ethoxyacetophenone in Diluent to obtain a solution having a known concentration of about 2.5 mg per mL.
Standard preparation
Dissolve an accurately weighed quantity of
USP Lansoprazole RS in
Internal standard solution to obtain a solution having a known concentration of about 5.0 mg per mL. Transfer 1.0 mL of this solution to a 50-mL volumetric flask, dilute with
Diluent to volume, and mix.
Assay preparation
Transfer about 50 mg of Lansoprazole, accurately weighed, to a 10-mL volumetric flask, dissolve in and dilute with Internal standard solution to volume, and mix. Transfer 1.0 mL of this solution to a 50-mL volumetric flask, dilute with Diluent to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 285-nm detector and a 4.6-mm × 25-cm column that contains 5-µm packing L1. The flow rate is about 1 mL per minute. Chromatograph the
Resolution solution, and record the peak responses as directed for
Procedure: the resolution,
R, between lansoprazole and lansoprazole related compound A is not less than 5. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the relative standard deviation for replicate injections is not more than 0.5%.
Procedure
Separately inject equal volumes (about 10 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the peak responses. Calculate the quantity, in mg, of C
16H
14F
3N
3O
2S in the portion of Lansoprazole taken by the formula:
500C(RU / RS),
in which
C is the concentration, in mg per mL, of
USP Lansoprazole RS in the
Standard preparation; and
RU and
RS are the peak response ratios obtained from the
Assay preparation and the
Standard preparation, respectively.