This test is provided to determine whether dietary supplement tablets or capsules disintegrate within the prescribed time when placed in a liquid medium at the experimental conditions presented below. Compliance with the limits on Disintegration stated in the individual monographs for dietary supplements is required except where the label states that the products are intended for use as troches, are to be chewed, or are designed as extended-release dosage forms. Dietary supplements claiming to be extended-release dosage forms must comply with standards other than disintegration to verify that the release of the dietary ingredients from the dosage form is for a defined period of time. Dietary supplements claiming to be extended-release dosage forms shall not be labeled as in compliance with USP unless a USP monograph exists for such product. Determine the type of units under test from the labeling and from observation, and apply the appropriate procedure to 6 or more units.
For purposes of this test, disintegration does not imply complete solution of the unit or even of its active constituent. Complete disintegration is defined as that state in which any residue of the unit, except fragments of insoluble coating or capsule shell, remaining on the screen of the test apparatus or adhering to the lower surface of the disk, if used, is a soft mass having no palpably firm core.
Apparatus
Apparatus A
Use the
Apparatus described under
Disintegration
701
for tablets or capsules that are not greater than 18-mm long. For larger tablets or capsules, use
Apparatus B.
Apparatus B
The apparatus
1 consists of a basket-rack assembly, a 1000-mL, low-form beaker for the immersion fluid, a thermostatic arrangement for heating the fluid between 35

and 39

, and a device for raising and lowering the basket in the immersion fluid at a constant frequency rate between 29 and 32 cycles per minute through a distance of not less than 53 mm and not more than 57 mm. The volume of the fluid in the vessel is such that at the highest point of the upward stroke the wire mesh remains at least 15 mm below the surface of the fluid and descends to not less than 25 mm from the bottom of the vessel on the downward stroke. At no time should the top of the basket-rack assembly become submerged. The time required for the upward stroke is equal to the time required for the downward stroke, and the change in stroke direction is a smooth transition rather than an abrupt reversal of motion. The basket-rack assembly moves vertically along its axis. There is no appreciable horizontal motion or movement of the axis from the vertical.
Basket-Rack Assembly
The basket-rack assembly consists of three open-ended transparent tubes, each 77.5 ± 2.5 mm long and having an inside diameter of 32.0 to 34.6 mm and a wall 2.0 to 3.0 mm thick; the tubes are held in a vertical position by two plastic plates, each about 97 mm in diameter and 7.5 to 10.5 mm in thickness, with three holes, each about 33 to 34 mm in diameter, equidistant from the center of the plate and equally spaced from one another. Attached to the under surface of the lower plate is 10-mesh No. 23 (0.025-inch) W. and M. gauge woven stainless-steel wire cloth having a plain square weave. The parts of the apparatus are assembled and rigidly held by means of three bolts passing through the two plastic plates. A suitable means is provided to suspend the basket-rack assembly from the raising and lowering device using a point on its axis.
The design of the basket-rack assembly may be varied somewhat provided the specifications for the glass tubes and the screen mesh size are maintained.
Disks
Each tube is provided with a perforated cylindrical disk 15.3 ± 0.15 mm thick and 31.4 ± 0.13 mm in diameter. The disk is made of a suitable, transparent plastic material having a specific gravity of between 1.18 and 1.20. Seven 3.15 ± 0.1-mm holes extend between the ends of the cylinder, one of the holes being through the cylinder axis and the others parallel with it and equally spaced on a 4.2 ± 0.1-mm radius from it. All surfaces of the disk are smooth.
2
Procedure
Uncoated Tablets
Place 1 tablet in each of the tubes of the basket and, if prescribed, add a disk to each tube. Operate the apparatus, using water or the specified medium as the immersion fluid, maintained at 37 ± 2

. At the end of 30 minutes, lift the basket from the fluid, and observe the tablets: all of the tablets disintegrate completely. If 1 or 2 tablets fail to disintegrate completely, repeat the test on 12 additional tablets. The requirement is met if not fewer than 16 of the total of 18 tablets tested disintegrate completely.
Plain Coated Tablets
Place 1 tablet in each of the tubes of the basket and, if the tablet has a soluble external sugar coating, immerse the basket in water at room temperature for 5 minutes. Then, if prescribed, add a disk to each tube, and operate the apparatus, using water or the specified medium as the immersion fluid, maintained at 37 ± 2

. At the end of 30 minutes, lift the basket from the fluid, and observe the tablets: all of the tablets disintegrate completely. If 1 or 2 tablets fail to disintegrate completely, repeat the test on 12 additional tablets. The requirement is met if not fewer than 16 of the total of 18 tablets tested disintegrate completely.
Delayed-Release (Enteric-Coated) Tablets
Place 1 tablet in each of the six tubes of the basket, and if the tablet has a soluble external sugar coating, immerse the basket in water at room temperature for 5 minutes. Then operate the apparatus using
simulated gastric fluid TS maintained at 37 ± 2

as the immersion fluid. After 1 hour of operation in
simulated gastric fluid TS, lift the basket from the fluid, and observe the tablets: the tablets show no evidence of disintegration, cracking, or softening. Operate the apparatus, using
simulated intestinal fluid TS, maintained at 37 ± 2

, as the immersion fluid for the time specified in the monograph. Lift the basket from the fluid, and observe the tablets: all of the tablets disintegrate completely. If 1 or 2 tablets fail to disintegrate completely, repeat the test on 12 additional tablets: not fewer than 16 of the total of 18 tablets tested disintegrate completely.
Buccal Tablets
Apply the test for Uncoated Tablets. After 4 hours, lift the basket from the fluid, and observe the tablets: all of the tablets disintegrate completely. If 1 or 2 tablets fail to disintegrate completely, repeat the test on 12 additional tablets: not fewer than 16 of the total of 18 tablets tested disintegrate completely.
Sublingual Tablets
Apply the test for Uncoated Tablets. At the end of the time limit specified in the individual monograph, all of the tablets disintegrate completely. If 1 or 2 tablets fail to disintegrate completely, repeat the test on 12 additional tablets: not fewer than 16 of the total of 18 tablets tested disintegrate completely.
Hard Shell Capsules
Apply the test for
Uncoated Tablets, using as the immersion fluid, maintained at 37 ± 2

, a 0.05 M acetate buffer prepared by mixing 2.99 g of sodium acetate trihydrate and 1.66 mL of glacial acetic acid with water to obtain a 1000-mL solution having a pH of 4.50 ± 0.05. Attach a removable wire cloth, as described under
Basket-Rack Assembly, to the surface of the upper plate of the basket-rack assembly. At the end of 30 minutes, lift the basket from the fluid, and observe the capsules: all of the capsules disintegrate except for fragments from the capsule shell. If 1 or 2 capsules fail to disintegrate completely, repeat the test on 12 additional capsules: not fewer than 16 of the total of 18 capsules tested disintegrate completely.
Soft Shell Capsules
Proceed as directed under Rupture Test for Soft Shell Capsules.
Use of Disks
vitaminmineral dosage forms
Add a disk to each tube unless otherwise specified in the individual monograph.
botanical dosage forms
Omit the use of disks unless otherwise specified in the individual monograph.
dietary supplements other than vitaminmineral and botanical dosage forms
Omit the use of disks unless otherwise specified in the individual monograph.
noteThe use of disks for enteric-coated tablets is not permitted.