Packaging and storage
Preserve in tight glass containers, and store between 2

and 8

. Do not freeze.
Labeling
Label it to indicate that the material is of recombinant DNA origin.
Identification
Proceed as directed in the tests for Peptide mapping and Electrospray mass spectrometry. The peptide map chromatographic profiles of the Test solution are similar to those of the Standard solution; the mass calculated by Electrospray mass spectrometry is within 20 Da of the theoretical mass.
Peptide mapping (see Biotechnology-Derived ArticlesPeptide Mapping
1055
)
Solution A
Prepare a filtered and degassed solution (1:1000, v/v) of trifluoroacetic acid in water.
Solution B
To 350 mL of acetonitrile add 150 mL of water and 425 µL of trifluoroacetic acid.
Mobile phase
Use variable mixtures of
Solution A and
Solution B as directed for
Chromatographic system. Make adjustments if necessary (see
System Suitability under
Chromatography
621
).
Tris buffer
Prepare a 0.1 M solution of tris(hydroxymethyl)aminomethane (Tris) in water, and adjust with hydrochloric acid to a pH of 8.0.
Dilute tris buffer
Dilute Tris buffer in water (50:50).
EDTA solution
Prepare a 0.1 M solution of ethylenediaminetetraacetic acid (EDTA) in water.
Sample diluent
To 5.76 g of guanidine hydrochloride add approximately 5 mL of Dilute tris buffer and 200 µL of EDTA solution. Dilute with Dilute tris buffer to a final volume of 10 mL.
Dithiothreitol solution
Prepare a 0.1 M solution of dithiothreitol in water.
Iodoacetamide solution
Prepare a 0.1 M solution of iodoacetamide in Tris buffer.
Trypsin solution
Prepare a solution containing 1 mg of trypsin per mL of 10 mM hydrochloric acid, and mix.
Standard solution
Add 20 µL of USP rAlbumin Human RS to 80 µL of
Sample diluent, and mix well. Add 5 µL of
Dithiothreitol solution, mix, and incubate at 37

for 75 minutes. Add 10 µL of
Iodoacetamide solution, mix, and incubate at 37

for 75 minutes in the dark. Add 100 µL of
Dilute tris buffer and 400 µL of water, and mix. Add 10 µL of
Trypsin solution, mix, and incubate at 37

with shaking for 24 hours. Separate insoluble material from the supernatant by centrifugation. Dilute the supernatant in
Solution A (50:50).
Test solution
Dilute the test sample in water to a final concentration of 50 mg per mL. Add 20 µL of this solution to 80 µL of
Sample diluent, and mix well. Add 5 µL of
Dithiothreitol solution, mix, and incubate at 37

for 75 minutes. Add 10 µL of
Iodoacetamide solution, mix, and incubate at 37

for 75 minutes in the dark. Add 100 µL of
Dilute tris buffer and 400 µL of water, and mix. Add 10 µL of
Trypsin solution, mix, and incubate at 37

with shaking for 24 hours. Separate insoluble material from the supernatant by pulse centrifugation. Dilute the supernatant in
Solution A (50:50).
Chromatographic system (see Chromatography
621
)
The liquid chromatograph is equipped with a 214-nm detector and a 4.6-mm × 25-cm column that contains 5-µm packing L1. The column temperature is maintained at 35

. The chromatograph is programmed as shown in
Table 1. below.
Table 1
Time (minutes) |
Solution A
(%) |
Solution B
(%) |
Flow Rate (mL per min) |
Elution |
05 |
95 |
5 |
0.5 |
isocratic |
575 |
95®60 |
5®40 |
0.5 |
linear gradient |
75100 |
60®40 |
40®60 |
0.5 |
linear gradient |
100104 |
40®0 |
60®100 |
0.5 |
linear gradient |
104108 |
0 |
100 |
0.5 |
isocratic |
108109 |
0®95 |
100®5 |
1.0 |
linear gradient |
109115 |
95 |
5 |
1.0 |
isocratic |
115116 |
95 |
5 |
0.5 |
isocratic |
116120 |
95 |
5 |
0.5 |
isocratic |
Procedure
Separately inject equal volumes (100 µL) of the Standard solution and the Test solution into the chromatograph, and record the chromatograms: the chromatographic profiles of the Test solution are similar to those of the Standard solution.
Electrospray mass spectrometry
Solution A
Dilute 200 µL of trifluroacetic acid in 200 mL of water.
Solution B
To 140 mL of acetonitrile add 180 µL of trifluroacetic acid and 60 mL of water.
Solution C
Dilute acetonitrile in water (50:50).
Solution D
To 5 mL of Solution C add 10 µL of formic acid.
Test solution
Dilute the test sample with water to obtain a final concentration of 10 mg per mL.
Desalted test solution
Desalt the Test solution as described below under Mass spectrometric system.
Mass spectrometric system (see Mass Spectrometry
736
)
The LC/MS spectrometer is equipped with an infusion system connected to an electrospray interface. The spectrometer is operated in the positive ion mode.
[NoteThe infusion system flow rate can be adjusted as needed. To assist in nebulization, the infusion system can contain a sheathing gas fluid.
] The liquid chromatographic system is equipped with a 280-nm detector and a 2.1-mm × 3-cm desalting cartridge.
1 The chromatograph is programmed as follows.
Time (minutes) |
Solution A
(%) |
Solution B
(%) |
Elution |
0®5 |
95 |
5 |
isocratic |
5®10 |
95®0 |
5®100 |
linear gradient |
10®15 |
0 |
100 |
isocratic |
The flow rate is 0.2 mL per minute. Equilibrate the capillary in
Solution C. Inject 20 µL of the
Test solution, record the chromatograms, and collect the eluate (i.e., the
Desalted test solution). Ensure that a single protein peak elutes.
System suitability solution
Accurately weigh about 2 mg of horse heart myoglobin. For each 2 mg weighed, add 589 µL of Water for Injection. Dilute 25 µL of this solution with 475 µL of Solution D.
System suitability
Inject 50 µL of the System suitability solution, and obtain and transform the spectrogram. A single peak with mass in the range 16,949 to 16,953 Da is found.
Procedure
Inject 50 µL of the Desalted test solution, and obtain and transform the spectrogram. The mass is within 20 Da of the theoretical mass.
pH
791
:
between 6.4 and 7.4 when diluted with 0.9% (w/v) sodium chloride to obtain a solution containing 1% (w/v) protein.
Purity (see Electrophoresis
726
)
Stock sample buffer2
Dilute a mixture of 4 mL of 0.5 M Tris hydrochloride pH 8.6, 0.5 mL of 0.1% bromophenol blue, and 2.0 mL of glycerol with water to 1 L.
Diluted sample buffer
Dilute the Stock sample buffer with water (1:1).
Native stock running buffer3
Dissolve 29 g of Tris base and 144 g of glycine in 900 mL of water. Mix well, and adjust with water to 1 L.
Running buffer
Dilute 1 volume of Native stock running buffer with 9 volumes of water.
Gel staining solution
Prepare a suitable Coomassie G-250based solution.
4
Native PAGE gel
Prepare a 14% TrisGlycine gel.
5
Test solution
Prepare a solution containing 4 mg of rAlbumin Human per mL of water. Add 500 µL of this solution to 500 µL of Stock sample buffer to obtain a solution having a concentration of 2 mg of rAlbumin Human per mL.
Calibration curve solutions
Dilute the Test solution quantitatively, and stepwise if necessary, with Diluted sample buffer to obtain standard curve solutions having known concentrations of 0.1 mg per mL, 0.02 mg per mL, 0.015 mg per mL, 0.01 mg per mL, 0.005 mg per mL, 0.002 mg per mL, and 0.001 mg per mL.
Gel loading scheme
Load 10-µL aliquots of the
Calibration curve solutions onto the gel from left to right in the following order:
Lane 1: 0.001 mg per mL
Lane 2: 0.002 mg per mL
Lane 3: 0.005 mg per mL
Lane 4: 0.01 mg per mL
Lane 5: 0.015 mg per mL
Lane 6: 0.02 mg per mL
Lane 7: Diluted sample buffer
Lane 8: Test solution
Lane 9: Test solution
Lane 10: Diluted sample buffer
Running the gel
Perform electrophoresis at 125 V, 35 mA, and 5.0 W, using Running buffer. Remove the gel from the apparatus after approximately 2 hours.
Gel staining
Place the gel in 100 mL of water, and shake gently with circumgyration for about 30 minutes. Pour approximately 50 mL of Gel staining solution into a staining container. Place the gel into the staining container, and allow the stain to completely cover the gel. Place the staining container on an orbital shaker, and stain the gel for 120 minutes with gentle shaking.
Destaining
Drain the Gel staining solution, and add 100 mL of water to the container to cover the gel. Place the container on an orbital shaker, and shake at low speed for about 60 minutes. Change the water, and repeat for a total of two washes.
Gel scan procedure
Set up a gel scanner according to the manufacturers instructions. Place the gel in the detector, and obtain a single image of all 10 lanes of the gel.
Data analysis
Perform image analysis of Lanes 1 to 6 to generate a linear calibration curve. Determine the linear regression equation of the standards by the least-squares method, with standard concentrations, in ng, as the dependent variable (
x) and the sample band intensity (optical density) as the independent variable (
y). Record the linear regression equation and the correlation coefficient,
r. A suitable system is one that yields a line having an
r2 of not less than 0.990.
Examine Lanes 8 and 9 (the Test solution lanes) for the presence of bands below the main albumin band. If bands are present below the main albumin band in either or both lanes, quantify the relative amount, in ng, of protein present in each band against the calibration curve. Convert the quantified value to a contaminant level in percentage by dividing the quantified value by a factor of 200. Calculate the purity of the sample by the formula:
100
CI
in which CI is the mean of the percentages of contaminant levels found in Lane 8 and Lane 9 (all the bands other than the albumin band), disregarding any band due to the Diluted sample buffer. The purity of the Test solution is not less than 99.0%. [NoteThe main albumin band is not quantitated. See test for Protein content below.]
High molecular weight proteins
Stock sodium azide solution
Dissolve 50 g of sodium azide in sufficient water to obtain a final volume of 250 mL.
Stock buffer
Dissolve 54.2 g of dibasic sodium phosphate dihydrate, 30.0 g of monobasic sodium phosphate dihydrate, and 284.0 g of anhydrous sodium sulfate in 1600 mL of water. Add 50 mL of Stock sodium azide solution, and dilute with water to 2000 mL.
Working buffer
Prepare a filtered and degassed mixture of water and Stock buffer (10:1).
Test solution
Dilute rAlbumin Human with water to a nominal concentration of 40 mg per mL.
Chromatographic system (see Chromatography
621
)
The liquid chromatograph is equipped with a 280-nm detector and a 7.8-mm × 30-cm column that contains 5-µm packing L59. The flow rate is 1.0 mL per minute.
Procedure
Inject 50 µL of the
Sample solution, record the chromatogram, and measure the peak responses. The peak due to the polymer is located in the part of the chromatogram representing the void volume. Calculate the percentage of polymer in rAlbumin Human taken by the formula:
100(rP / rs)
in which
rP is the peak response for the rAlbumin Human polymer; and
rs is the sum of the responses of all of the rAlbumin Human related peaks: not more than 1.0% is found.
Protein content
Copper sulfate solution
Dissolve 0.6 g of copper sulfate pentahydrate and 6.0 g of potassium sulfate
6 in 10.0 mL of sulfuric acid low in nitrogen.
Test solution
Dilute 0.5 g of rAlbumin Human with 2.5 mL of 0.15 M sodium chloride to obtain a solution containing about 3.3 mg of protein per mL.
Blank
Dilute 0.1 g of glycine with 3.0 mL of the 0.15 M sodium chloride used to make the Test solution.
Procedure
To 3.0 mL of the
Test solution and the
Blank, in suitable distillation tubes, add 5 mL of
Copper sulfate solution. Incubate at 420

for a minimum of 2 hours, or until the residues appear white. When the solutions are cool, transfer the residues quantitatively with a minimum quantity of water to a micro-Kjeldahl flask, and determine the residues, using
Method II under
Nitrogen Determination
461
. Multiply the result, corrected for the
Blank and for the specific gravity of the
Test solution, by 6.25 to calculate the quantity of protein. It contains not less than 95% and not more than 105% of the quantity of protein stated on the label.
Sodium content
Diluent
Dissolve 1.0 g of cesium chloride in sufficient water to obtain a final volume of 1000 mL.
Test solution
Accurately prepare 40 mL of a solution of rAlbumin Human in Diluent having a concentration of approximately 80 µg per mL of rAlbumin Human.
Reference solutions
Prepare four solutions of sodium chloride in Diluent having concentrations of 0.5 mg per mL, 1.00 mg per mL, 1.50 mg per mL, and 2.00 mg per mL.
Procedure
Set a suitable atomic absorption spectrometer capable of analyzing in emission mode to a wavelength of 589 nm. Operate the atomic emission spectrometer in accordance with the manufacturer's instructions. Introduce a blank solution (
Diluent) into the atomic generator, and adjust the instrument reading to zero. Determinations are made by comparison with the
Reference solutions of known concentration. If the
Test solution emission exceeds that of the
Reference solution with the highest concentration, dilute the
Test solution with
Diluent. Introduce the most concentrated
Reference solution into the instrument, and adjust the sensitivity to obtain a suitable reading. Introduce the
Test solution and each
Reference solution into the instrument at least three times, and record the steady reading. Rinse the apparatus with blank solution each time, and ascertain that the reading returns to its initial blank value. Plot the mean of the readings obtained for the
Reference solutions against their respective sodium concentrations. From the standard curve, calculate the sodium concentration content in the
Sample solution, and adjust for the specific gravity of the rAlbumin Human (see test for
Protein content): the concentration of sodium is not less than 120 mM and not greater than 160 mM.
NF27